Operating manual • EnglishKäyttöohje • SuomiBruksanvisning • SvenskaBruksanvisning • NorskBrugsanvisning • DanskGebrauchsanweisung • DeutschGebruiksaa
ENTo adjust the spool brake in models 300, 300P and 300RC, do the following:AAdjust the spool brake force through the hole in the spool locking mechan
ENTo change feed rolls, do the following: 1. Remove the feed rolls by unscrewing their xing screws. 2. Insert the new feed rolls into their place.
EN4. USING THE MACHINEBefore starting to use the Kemppi ArcFeed wire feeder, you must be aware of the power source type you are using ( either CC, co
ENAdjusting the welding values in CC mode:In CC mode, the display shows the open-circuit voltage and a reference value for welding current. The refere
ENHow to use the welding gun in 2T operating mode:1. Press the gun trigger down to start welding.2. Release the gun trigger to stop welding.How to u
EN4.2 USING THE INSIDE CONTROLSBURNBACKWIRE INCHGAS TESTPOST GAS1234 WIRE INCHGAS TESTPOST GASBURNBACKWIREINCHGASTESTPOSTGAS1 2 3 4ArcFeed 200
EN5. MAINTENANCE5.1 DAILY MAINTENANCE Do the following always before starting to use the machine: • Check the tightness of the earthing cable conne
EN6. ORDERING NUMBERSOrdering numberWire feedersKemppi ArcFeed 2006120200Kemppi ArcFeed 3006120300Kemppi ArcFeed 300P6120310Kemppi ArcFeed 300RC61203
EN7. TECHNICAL SPECIFICATIONSKemppi ArcFeed 200 300/300RC 300PRated power (W)150 150 150Welding wire typesFlux-cored wires, ø (mm)1.2…2.0 1.2…2.0 1.2
EN17ArcFeed 200, 300, 300P, 300RC / © Kemppi Oy / 1117
www.kemppi.com1931570 1117KEMPPI OYHennalankatu 39PL 13FIN-15801 LAHTIFINLANDTel +358 3 899 11Telefax +358 3 899 [email protected]
OPERATING MANUALEnglishArcFeed 200, 300, 300P, 300RC / © Kemppi Oy / 1117
ENCONTENTS1. PREFACE ...
EN1. PREFACE1.1 GENERALCongratulations on your choice of the Kemppi ArcFeed wire feeder. Used correctly, Kemppi products can signicantly increase t
EN1.3 INTRODUCTIONThe Kemppi ArcFeed is a voltage sensing wire feeder for MIG/MAG welding. It can be combined with a variety of power sources of vari
EN2. BEFORE USE2.1 CONNECTING THE CABLESBefore starting to use the Kemppi ArcFeed, the necessary cable connections must be done in the power source
EN2.4 INSTALLING THE MIG/MAG WELDING GUNAfter mounting the wire spool, connect the welding gun cable to the connector (3) in the front of the feeder.
EN1. Open the locking lever (1) and remove the lower feed rolls (2). Open the screw (4) and remove its washer. Then remove the gear wheel (5) from mo